Service Lift AS1735.4
Works by Others.
LIFT SHAFT: Construction of the lift shaft by builder, to Easy Living Home Elevators specifications.
Please note: The front is to be left out of the shaft enclosure until after service installation.
The tower structure is of standard design and is suitable to support the lift only and cannot be used as a structural support for other equipment or building.
PIT: Lift pit must be kept dry. No seepage or damp areas are allowed.
This is a Work Cover requirement and will affect the long-term condition of the equipment.
SHAFT & PIT FINISH: A smooth and plumb surface shall be provided. Ensure shaft and pit is dry, stripped, cleaned, holes patched and free of construction debris and formwork nails or other protrusions prior to Easy Living Home Elevators start on site.
DOOR OPENING SIDES: Complete front face of lift shaft after the lift has been installed.
SHAFT ROOF: Lift shaft roof must be a solid, non-perforated material, permanently fixed and of sufficient strength to support the weight of a person, nominally 120kg.
SHAFT BARRICADE: Supply, install and maintain shaft protection barricades to each lift entrance.
SHAFT LIGHTING: By Easy Living Home Elevators.
SHAFT CONDUIT: By Easy Living Home Elevators.
MACHINE ROOM: Construction of the machine room enclosure (if machine room is preferred by the customer) to Easy Living Home Elevators specifications.
MACHINE ROOM DOOR: If machine room is provided, supply and install fire door with closer and night-type latch to the lift machine room entrance. Minimum door dimension is 900mm x 2000mm clear. The door must open outwards from the lift machine room.
LIFT MOTOR ROOM: Lift Motor Room Door (LMR) is standard sheet steel type and is not fire rated.
CABINET ACCESS: A clear permanent access must be provided to the lift control cabinet.
ELECTRICAL: Provide electrical supply to the Lift Cabinet and terminate to a lock off isolator, to the Easy Living Home Elevators lift sub-board. 20 Amp three phase dedicated supply is required. The lift supply must be from a dedicated circuit.
- Lift supply cabling by electrical contractor.
- Wiring to comply with AS3000 requirements.
LIGHTING: Provide lighting, emergency lighting and general purpose power to the lift machine room.
ISOLATOR & LIGHT: The electrical isolator and machine room light switch are to be located opposite the machine room door hinge.
SERVING HEIGHT: The serving height for sill loading lifts shall be between 800 and 900mm from Finished Floor Level (FFL)
LANDING DOORS: By Easy Living Home Elevators.
DOOR FINISHING: Door finishing by builder.
LANDING BUTTON: Landing buttons are typically located within the frame but if installed onto a wall, the landing button finishing is by builder.
LIFTING EYE: Provide suitable lifting eye beam on the shaft roof to support approximate load of 250kg.
STORAGE AREA: Provide dry, clean and safe storage of the lift equipment on site. The location of the storage area shall be agreed with Easy Living Home Elevators and be close to the lift shaft and machine room.
STORAGE: Should the site not be ready for the installation works to commence upon equipment arrival, storage costs will apply.
SCAFFOLDING: Lift shaft scaffolding to be supplied to Easy Living Home Elevators specifications.
MAKING GOOD: For masonry shafts, building in and/or making good to lift doorframes, penetrations, floor sills and landing panels.
BUILDERS LIFT: There is no provision for the lift to be used as a builders lift.
BINS: Bins to be supplied for rubbish removal.
Note: Easy Living Home Elevators Pty Limited reserves the right to make changes to the above information at any time, without notice.